Rhw-2/Rhh/Use-2 Building Wire - Aluminum UL Certificate Rated 600 Volts

Model NO.
RHH RHW RHW-2 XHH XHHW XHHW-2
Material Shape
Round Wire
Range of Application
Conduit or Recognized Raceways for Services
Certification
ISO9001, CE, CCC, RoHS, VDE
Brand
Huatong
Standard
UL44, Icea 95-658
Rated Voltage
Low Voltage 600V
Transport Package
Coils and Drums
Specification
14awg-1000mcm
Trademark
Renda
Origin
China
HS Code
8544492100
Production Capacity
200000m/Month
Reference Price
$ 0.02 - 0.02

Product Description

Rhw-2/Rhh/Use-2 Building Wire - Aluminum UL Certificate Rated 600 Volts

APPLICATION
 

Aluminum conductors are primarily used in conduit or recognized raceways for service and feeder wiring as specified in the National Electrical Code. XHHW-2 conductors may be used in wet or dry locations at temperatures not to exceed 90°C. Voltage rating for XHHW-2 conductors is 600 volts. Suitable for use in Health Care Facilities per section 517.160 of the NEC where a dielectric constant of 3.5 or less may be specified. This product is designed to be installed without the application of pulling lubricant.

PRODUCT FEATURES
Compact stranded 8000 Series aluminum alloy conductor. Insulation is an abrasion, moisture, heat and sunlight resistant black cross-linked polyethylene.
Cable can be installed without pulling lubricant.
CT rated available when requested on sizes 1/0 AWG and larger.

STANDARDS & REFERENCES
Aluminum Type XHHW-2 conductors comply with the following:
• ASTM- All Applicable Standards
• UL Standard 44
 UL listed as Type XHHW-2.
• NOM-ANCE 90° C
• Federal Specification A-A-59544
• National Electrical Code, NFPA 70, 2014 Edition
• NEMA WC-70 (ICEA S-95-658) Construction Requirements
• RoHS/Reach Compliant
Conductor sizes 6 AWG and larger are listed and marked sunlight resistant in all colors.


CONSTRUCTION
Conductor: compact copper or AA-8000 series aluminum alloy, compact stranded
Insulation:Cross-linked polyethylene(XLPE) insulation with property of heat.Moistrure and abrasion resistance and flame retardant.
Color :Available in black, white, red, blue, brown, orange, yellow, purple, gray, and green.

Specifications:
Conductor (AWG or MCM)StrandingInsulationOutsideWeight per 1000 ft.Ampacity
ThicknessDiameter(AMPS) *
(mls)(in)(lbs)90° C
67/w450.263960
47/w450.3055775
27/w450.3684100
119/w550.415108115
1/019/w550.45132135
2/019/w550.49161150
3/019/w550.54198175
4/019/w550.59244205
25037/w650.655292230
30037/w650.705344255
35037/w650.75396280
40037/w650.795448305
50037/w650.87550350
60061/w800.98671385
70061/w801.04774420
75061/w801.075824435
90061/w801.1610.979480
100061/w801.231079500


1. Data are approximate and subject to normal manufacturing tolerances. 
2. Standard lengths are subject to normal manufacturing tolerance of +/- 10% 
3. Two, Three or four conductors can be paralleled on a reel. 
4. 90°C- XHHW-2 wet or dry locations.
5.Package:A-500' B-2,500' C-1,000' D-5,000'
UL Certificate for XHHW,SER,SEU,MC Cable
Rhw-2/Rhh/Use-2 Building Wire - Aluminum UL Certificate Rated 600 Volts

Rhw-2/Rhh/Use-2 Building Wire - Aluminum UL Certificate Rated 600 Volts

 
Rhw-2/Rhh/Use-2 Building Wire - Aluminum UL Certificate Rated 600 VoltsRhw-2/Rhh/Use-2 Building Wire - Aluminum UL Certificate Rated 600 VoltsRhw-2/Rhh/Use-2 Building Wire - Aluminum UL Certificate Rated 600 VoltsRhw-2/Rhh/Use-2 Building Wire - Aluminum UL Certificate Rated 600 VoltsRhw-2/Rhh/Use-2 Building Wire - Aluminum UL Certificate Rated 600 VoltsRhw-2/Rhh/Use-2 Building Wire - Aluminum UL Certificate Rated 600 Volts

 

GIGATA.VN, 2023