170kv/220kv/245kv Outdoor Hv 2 Columns Central Break Disconnector

Model NO.
GW4
Number of Poles
Three Pole
Grounding
Single Ground
Structure of Operating
Electric
Certification
ISO, IS9001, ISO9001
Transport Package
Wooden
Specification
245KV
Trademark
HEMG
Origin
China
Production Capacity
50000
Reference Price
$ 8,100.00 - 9,000.00

Product Description


170kv/220kv/245kv Outdoor Hv 2 Columns Central Break Disconnector
 
SPECIFICATION OF 245KV DISCONTECTOR 
3.1.2 DISCONNECTORS(ISOLATORS) 
Item                                                             NoDescription ParticularsOFFERED
245kV245KV
1Manufacturer  
1.1Name Pars Switch Co.HEMG
1.2Country of origin IRANCHINA
2Type/Designation NSA245/3150D DS,DS+ESGW4-252KV
2.2State whether end posts,vertical,centre break,etcH.C.B.CENTRA BREAK ,2 COLUMNS
2.3Three phase or single phase3Phase3 PHASES
2.4Earthing switch incorporatedNVA245JW10-252KV
3Type of operating mechanism BCM-FSCRJ2
4Power at normal voltage required for:  
4.1Operating coil                                                             W------(--)
4.2Motor (where provided)                                              W170370W
5Operating characteristics:  
5.1Total time from initiation of opening operation to           s     isolator in fully open position 3 up to 510S
5.2Time from contact separation to extinction of               s     capacitive arc3 up to 510S
5.3Total time from initiation of opening operation to time    s     when isolator gap can withstand phase voltage3 up to 510S
6Rated voltage                                                             kV245245KV
7Rated normal voltage: a) for coupler bay                      A31503150A
                                 b) for other bays                        A31503150A
8Maximum short time current                                   for(1  
                                                                          second/3  
                                                                          second )  
8.1Disconnector                                                        kA rms50(1S)50KA(1S)
8.2Earth switch                                                         kA rms50(1S)50KA(1S)
9Total mass of three phase isolator complete               Kg1100(shipping)2665(SHIPPING)
10Type pf earthing switch (where provided)NVAJW10-252KV
11Type of operating mechanism for earthing switch BCM-FSCRJ3
12Basic insulation level at site altitude (IEC 694)  
12.1Lighting impulse withstand level (1.2/50μs wave)                    positive and negtive  
12.1.1To earth and between phases in the closed position    kVp10501050KV
12.1.2Between phases in the open position                         kVp10501050KV
    
Item                                                             NoDescription ParticularsOFFERED
245kV245KV
12.1.3Across open gap   
12.1.3.1Lightning impulse                                                        kVp12001200KV
12.1.3.2Lighnting impulse/Bias                                                kVp+12001200KV
                                                                                 kV ACP  
12.2Switching surge withstand level (250/2500μs wave)  
at site altitude - positive and negtive          dry/wet  
12.2.1To earth and between phases in closed position            kVpN.A.N.A
12.2.2Between phases in open position                                 kVpN.A.N.A
12.2.3Across open gap   
12.2.3.1Switching surge                                                          kVpN.A.N.A
12.2.3.2Switching surge/Bias                                                  kVp+N.A.N.A
                                                                                 kV ACP  
12.3Power frequency withstand voltage at site altitude    dry/wet  
12.3.1To earth and between phases in closed position - 1       kV          minute460460KV
12.3.2To earth and between phases in open position - 1         kV           minute460460KV
12.3.3Across open gap -1minute                                             kV520520KV
13In air clearances:  
13.1Phase to earth aecing distance                                       mmplease see DIM. Prints2100MM
13.2Phase to phase distance in open position                      mmplease see DIM. Prints2550MM
13.3Distance between terminals of open isalator                 mmplease see DIM. Prints2200MM
14Support insulators  
14.1ManufaturerChinaCHINA
14.2Type, designation of unitBrown glazed porcelain BROWN GLASED PROCELAIN
14.3Minimum creepage to earth (to IEC 815)                      mm75007500MM
15Protected creepage distance                                           mm32043205MM
16Radio influence voltage level measured at 1.1 times      μV             Us/3 at 1MHz25002500MM
17Maximum capacitive current that can be interrupted      A               by the disconnector 1A
Item                                                             NoDescription ParticularsOFFERED 
245kV245KV
18Operating mechanism for disconnecting switch:  
18.1Type BCM-F(MOTOR&HAND)SCRJ2
18.2Operating voltage - rated/ min for :  
(a) operating coil (if any)                                     V----- 
(b)Motor                                                              V220 VDC220VDC
19Opening time- from the moment when the coil is                               energised until the complete extinction of arc                between opened contacts( under system highest              voltage condition)3 up to 510S
20Operation time - from the moment when the coil is                           energised until the disconnectoon of operating motor      in limit open disconnected positioning.3 up to 510S
21Operating mechanism for earthing switch  
(a) type BCM-F(MOTOR&HAND)SCRJ3
(b) operating voltage- rated/min/max220 VDC220VDC
(c)rated power170370W
22Total weight of complete disconnecting switch ( one or                          three poles).1100(shipping)2665KG(SHIPPING)
23Type test certificate details   
(a)testing stationCESI - ITALYKEMA
(b)certificate numbersA6020791TIC3010-03
3.1.3EARTHING SWITCHES  
Item                                                             NoDescription Particulars 
245kV245KV
1Manufacturer  
1.1Name Pars Switch Co.RGHY
1.2Country of origin IRANCHINA
2Type / Designation NVA245(associated with earthing switch )/outdoorJW10-252
3Type of contactsPINPIN
4Materials of contact surfaceSliver Plated CopperSILVER PLATED COPPER
5Rated short time current   
                (a) For 1 sec                               KA(rms)5050KA
                (b) For 2 sec                               KA(rms)---- 
6Rated peak short current                              KA(peak)125125KA
7Gap between poles                                       MmPlease see DIM.Prints2050MM
8One minute power frequency withstand           kV           voltage cross open gap      Please see type test reports460KV
9Lightning impulse withstand voltage Please see type test reports1050KV
10Operating mechanism   
(a)Type MOTOR&HAND(BCM-F)SCRJ3
(b)Operating voltage - rated/min                      V220 VDC220VDC
(c)Rated power                                             W170370W
11Main dimensions                                         MmPlease see DIM.PrintsSEE THE DRAWING 
12Total weight                                                KgPlease see DIM.PrintsSEE THE DRAWING 
13Type test certificate details   
(a) Testing station/authorityCESI-ITALYKEMA
(b)Certificate number A6020791TIC3010-03
(c)Applied standardsIEC62271-102IEC62271-102
14Creepage distance                                        mm75957595MM

 

Isolation Switch