| Inverter Model | Power (kW ) | Current(A) | Packing Size (mm ) | Gross Weight (kg) | Net Weight (kg) |
| ZVF300-G037/P045T4M | 37/45kW 380V | 75/90A | 700*375*400mm/1PCS | 36kg | 31k |


| Item | Item Description | |
| Input | Rated voltage& Frequency | Single /Three phase 220VAC . Three phase 380V.50Hz/60Hz |
| Allowable Voltage range | Voltage fluctuate range:-20%~+20% Voltage unbalance rate:<3%;Frequency fluctuation:≤5% | |
| Output | Rated voltage | three phase 0~ input AC voltage |
| Frequency | 0.00~600.00Hz | |
| Overload capacity | Type G:150% 1minute,180% 1 second,200% transient protection Type P:120% 1minute,150% 1 second,180% transient protection | |
| Control Function | Modulation mode | Optimal space voltage vector PWM modulation |
| Control mode | Sensorless vector control (SVC), V/F control . Torque control | |
| Frequency accuracy | Digital setting::Max. Frequency×±0.01% Analog setting:Max. Frequency×±0.2% | |
| Frequency resolution | Digital setting :0.01HZ; Analog setting :Max. Frequency x0.1%. | |
| Starting frequency | 0.00~10.00Hz | |
| Torque lift | Automatic torque lift: To lift the torque automatically according to the output current. Manual torque lift, Range: 0.1_30.0% | |
| Slip compensation | Setting range:0~150%,The inverter output frequency can be auto-regulated within this range according to the motor load, so as to reduce the speed variation of the motor due to load fluctuation. | |
| Acceleration/deceleration time | Minutes/Seconds can be selected as time unit .0.1~3600 can be set in sequence . | |
| Carrier frequency | 1.0~15.0KHz | |
| Jog function | Jog frequency range:0.01~600.00Hz, Jog acceleration /deceleration time 0.1~3600.0 can be set. | |
| V/F curve | 1:linear curve;2:quadratic;3:user defined V/F curve | |
| Ambient | Place to be used | Indoor location free from direct exposure to sun light, high humidity or dew condensation, high levels of dust, corrosive gas, explosive gas, inflammable gas, oil mist, salt and etc |
| Altitude | Below 1000 M | |
| Ambient Temperature | -10 C to +45 C (Bare Machine: -10 C to+50 C) | |
| Humidity | 20%-90% RH without dew condensation | |
| Vibration | <0.5G | |
| Storage temperature | -20~+60C | |
| Structure | Protection class | IP20 |
| Cooling mode | Forced air cooling | |
| Installation mode | Wall mounted or floor-type actuator |