| Items | Specification |
| Analog Input | |
| Channels |
Channel 1:vibration(ICP accelerometer),Voltage(±21V AC or DC)
Channel 2:vibration(ICP accelerometer),Voltage(±21V AC or DC),tacho channel |
| Transducer | Accelerometer, Velocity, Displacement, voltage transducer |
| Signal range | ±21V |
| A/D conversion | 24 bit |
| Analog measurement | |
| Integration | once, twice integration |
| Maximal analysis frequency | 40kHz(dual channel Maximal: 20kHz) |
| Sampling frequency | 256Hz - 102.4kHz |
| Dynamic signal range | 96dB |
| Precision | 1%( 0.1dB) |
| Signal processing | |
| Configuration | Sampling frequency, low band pass filter, Sampling length,users can set any value as needed. |
| Lines | 400, 800, 1600, 3200, 6400, 12800 |
| Time domain Sampling | 1024, 2048, 4096, 8192, 16384, 32768 |
| Window function type | Hanning, Rectangle window |
| Averaging | Linearity, peak hold |
| Averages | 1,2,4,8,16,32,64,128 |
| Analysis | |
| Long time domain waveform | Maximal waveform is 10M, maximal analysis frequency of Dual-channel is 10KHz, maximal analysis frequency of single channel is 20K |
| Overall value | Minimum interval: 0.1 sec |
| XPM measurement | view XPM and phase difference spectrum simultaneously |
| Dynamic balance | On site 1 or 2 plane dynamic balance by Influence coefficient method |
| RPM measurement range for balancing | 300~18,000RPM |
| Coast up/down testing | Equal time intervals, Equal RPM intervals |
| Basic index | |
| LCD | Colorful LCD, 320×240pixles, contrast adjustable |
| Keys | 22 keys |
| Communication | USB, 900KB/s |
| Storage capacity | 1G |
| I-Button | DS1990A |
| Communication | USB 2.0 |
| Battery | Rechargeable Li-ion battery, charging time around 4 hours; working Time (Continuous) >10 Hours; two channel working time >8 Hours |
| Temperature | (-10~50)ºC |
| Humidity | 95% RH without condensate |
| Protection grade | IP65 |
| Dimension | 190 X110 X50mm |
| Weight | 660g |